Sangamo RSTAT1, Bi-metallic, White, Standard
_Erp: Class 1, +1%
_Voltage supply: 230V AC 50-60Hz
_Temperature setting range: 10 degree C to 30 degree C
_Current eating: 10(3) Amp
_Terminal differential: Approx 4 degree C
Sangamo Q550 Astro Dials come in 4 variations depending on where you are in the British Isles the switch is adjusted to match the slight differences in sunrise and sunset times. Simply locate where you are on the map and add the number on to the end of the part number or select the equivalent zone. The ON operation always tracks SUNSET while the OFF operation can be made either to track SUNRISE, or to occur at a fixed time between 8:30pm and 1:00am. A Òday omissionÓ device allows you to select any number of days in the week on which the switching cycle can be disabled. The Solar Time Switch is ideal for applications which require control linked to sunset and sunrise times. Popular applications for solar time switches include street, stairwell and security lighting. Once set, the switches track SUNSET and SUNRISE throughout the year, without the need to sense light levels. This avoids the installation and maintenance problems associated with photo sensing devices and means they can be left to operate unattended for years. Legal DisclaimerThis is brand new product, still in original retail packaging, but packaging is not in great condition
_Zone 1 - 50¡N (Plymouth, Southampton, Brighton)
_Programming: 24 hour with 1 ON/OFFÊoperations
_Current rating: 20A
_Connection pins: 3
Sangamo Q550 AstroÊDials come in 4 variations depending on where you are in the British Isles the switch is adjusted to match the slight differences in sunrise and sunset times. Simply locate where you are on the map and add the number on to the end of the part number or select the equivalent zone. The ON operation always tracks SUNSET while the OFF operation can be made either to track SUNRISE, or to occur at a fixed time between 8:30pm and 1:00am. A Òday omissionÓ device allows you to select any number of days in the week on which the switching cycle can be disabled. The Solar Time Switch is ideal for applications which require control linked to sunset and sunrise times. Popular applications for solar time switches include street, stairwell and security lighting. Once set, the switches track SUNSET and SUNRISE throughout the year, without the need to sense light levels. This avoids the installation and maintenance problems associated with photo sensing devices and means they can be left to operate unattended for years.
_Zone 1 - 50¡N (Plymouth, Southampton, Brighton)
_Programming: 24 hour with 1 ON/OFFÊoperations
_Current rating: 20A
_Connection pins: 3
_Day omit dial: yes (omits the ÔonÕ operation)
Flexible, 7 day, fully programmable electronic control with battery reserve, 4-pin base. Allows up to 48 ON and 48 OFF operations per day (96 operations per day) and automatically allows for the changes between British Summer Time (BST) and Greenwich Mean Time (GMT). General purpose timeswitch for heating, ventilation equipment control applications etc.Box ContainsSangamo E855
_7 day programme
_4-pin digital time switch
_Up to 48 ON and 48 OFF (96 operations per day).
_Each day can be programmed independently
Sangamo Time Switch E854240
_Mounting: Surface Mounting
_Current rating: 20A resistive for SPST
_Base type: 3-pin
_Reserve: Rechargeable battery will retain memory for typically 20 days
_Temp override facility: (Manual Button) Two hour boost - when programme ÒOFFÓ, Advance to ÒOFFÓ when programme ÒONÓ and will remain ÒOFFÓ until next ÒONÓ operation
A data key for use with digital time switches that have a key programming feature. A programming key enables you to save the program currently held in the product. You could use this programming key as an alternative program option with the product itself being re-programmed to different settings.
_Works with: 72101, 72201
_plus 72112, 72212, 25162
_plus 26404, 23871, 23872.
Designed for the Sangamo S250, Q550 and E850 models, the conduit box is for interior use and is made of pressed steel with a Black enamel finish.
_Will accept 3/4in or 20mm conduit
_Fixings supplied
_Robust steel construction with Black enamelled finish
The Q586 is a 24 hour time switch. A Òday omissionÓ device allows you to select any number of days in the week on which the switching cycle will be disabled. An early ÒONÓ operation can be assigned to one day only of the week. There is also a manual override button for your convenience. 100hr Battery Reserve.
_Programming: 24 hour with 2 on/off operations
_Current Rating: 20A
_Connection Pins: 4
_Battery Reserve: 100 hours
_Day Omit Dial: Yes (Early ÔONÕ operation)
The 24 hour programming changeover time switch performs the same sequence of switching operations on each day and can be quickly and easily set using the small manual levers on the dial. A ÒdayÓ device allows you to select any number of days in the week on which the switch will remain ON. A general purpose changeover time switch suitable for applications where alternating between two circuits is necessary e.g. boilers, compressors.
_Programming: 24 hour with 2 ON/OFFÊoperations
_Current rating: 20A
_Connection pins: 4
_Day omit dial: yes (omits the ÔonÕ operation on one circuit only)
Sangamo Q550 AstroÊDials come in 4 variations depending on where you are in the British Isles the switch is adjusted to match the slight differences in sunrise and sunset times. Simply locate where you are on the map and add the number on to the end of the part number or select the equivalent zone. The ON operation always tracks SUNSET while the OFF operation can be made either to track SUNRISE, or to occur at a fixed time between 8:30pm and 1:00am. A Òday omissionÓ device allows you to select any number of days in the week on which the switching cycle can be disabled. The Solar Time Switch is ideal for applications which require control linked to sunset and sunrise times. Popular applications for solar time switches include street, stairwell and security lighting. Once set, the switches track SUNSET and SUNRISE throughout the year, without the need to sense light levels. This avoids the installation and maintenance problems associated with photo sensing devices and means they can be left to operate unattended for years.
_Zone 1 - 50¡N (Plymouth, Southampton, Brighton)
_Programming: 24 hour with 2 ON/OFFÊoperations
_Current rating: 20A
_Connection pins: 4
Designed to give automatic frost protection to boilers and pipework as well as the fabric of the building. The thermostat should be fitted in the coldest areas, e.g. loft spaces, floor voids, garages, etc and is wired so as to over-ride other controls and switch on your heating if the temperature falls to a point where damage could occur.